CVE-2025-52988
An Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the CLI of Juniper Networks Junos OS and Junos OS Evolved allows a high privileged, local attacker to escalated their privileges to root. When a user provides specifically crafted arguments to the 'request system logout' command, these will be executed as root on the shell, which can completely compromise the device. This issue affects: Junos OS: * all versions before 21.2R3-S9, * 21.4 versions before 21.4R3-S8, * 22.2 versions before 22.2R3-S6, * 22.3 versions before 22.3R3-S3, * 22.4 versions before 22.4R3-S6, * 23.2 versions before 23.2R2-S1, * 23.4 versions before 23.4R1-S2, 23.4R2; Junos OS Evolved: * all versions before 22.4R3-S6-EVO, * 23.2-EVO versions before 23.2R2-S1-EVO, * 23.4-EVO versions before 23.4R1-S2-EVO, 23.4R2-EVO.
Key facts
- CVSS score
- 6.7 (v3.1)
- Severity
- MEDIUM
- CVSS vector
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H- Weakness (CWE)
- CWE-78
- EPSS score
- 0.4% (37th percentile)
- In CISA KEV
- No
- In EU EUVD
- Yes (EUVD-2025-21167)
- Published
- July 11, 2025
- NVD last modified
- June 17, 2026
- Status
- Analyzed
EU Vulnerability Database (EUVD)
This vulnerability is also tracked by ENISA as EUVD-2025-21167 in the EU Vulnerability Database. Last updated in EUVD on February 26, 2026.
View on the EU Vulnerability DatabaseAffected products
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
and 50 more…
Certified products that may be affected
5 FIPS 140 or Common Criteria certified products, from automated matching by sec-certs.org.
- Junos Space Network Management Platform, with or without Network Director and with or without Security Director in JA2500 - Juniper Networks, Inc. - FIPS 140 3816 - historical
- Juniper Networks SRX345/SRX345-DUAL-AC with Junos 15.1X49-D110 - Juniper Networks, Inc. - FIPS 140 3247 - historical
- Junos-FIPS 10.4 L2 OS Cryptographic Module - Juniper Networks, Inc. - FIPS 140 1813 - historical
- Junos-FIPS 10.4 L1 OS Cryptographic Module - Juniper Networks, Inc. - FIPS 140 1772 - historical
- JUNOS-FIPS - Juniper Networks, Inc. - FIPS 140 602 - historical
References
- https://supportportal.juniper.net/JSA100095(Vendor Advisory)
Last updated September 17, 2026 · Source: NVD, CISA KEV, FIRST.org EPSS
Query CVEs from your AI assistant
The CVE/NVD Explorer brain answers CVE questions directly inside Claude, ChatGPT, or any MCP assistant — always up to date, no setup. Add it once and stop pasting advisories into chat.
Add the CVE brain