CVE-2017-2345
On Junos OS devices with SNMP enabled, a network based attacker with unfiltered access to the RE can cause the Junos OS snmpd daemon to crash and restart by sending a crafted SNMP packet. Repeated crashes of the snmpd daemon can result in a partial denial of service condition. Additionally, it may be possible to craft a malicious SNMP packet in a way that can result in remote code execution. SNMP is disabled in Junos OS by default. Junos OS devices with SNMP disabled are not affected by this issue. No other Juniper Networks products or platforms are affected by this issue. NOTE: This is a different issue than Cisco CVE-2017-6736, CVE-2017-6737, and CVE-2017-6738. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D44, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F2-S18, 15.1F6-S7, 15.1R4-S8, 15.1R5-S5, 15.1R6-S1, 15.1R7; 15.1X49 prior to 15.1X49-D100, 15.1X49-D110; 15.1X53 prior to 15.1X53-D231, 15.1X53-D47, 15.1X53-D48, 15.1X53-D57, 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R4-S4, 16.1R5; 16.2 prior to 16.2R2, 16.2R3; 17.1 prior to 17.1R1-S3, 17.1R2, 17.1R3; 17.2 prior to 17.2R1-S1, 17.2R2; 17.2X75 prior to 17.2X75-D30. Junos releases prior to 10.2 are not affected.
Key facts
- CVSS score
- 9.8 (v3.0)
- Severity
- CRITICAL
- CVSS vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H- Weakness (CWE)
- CWE-20
- EPSS score
- 3.6% (89th percentile)
- In CISA KEV
- No
- In EU EUVD
- Yes (EUVD-2017-11528)
- Published
- July 17, 2017
- NVD last modified
- June 17, 2026
- Status
- Modified
EU Vulnerability Database (EUVD)
This vulnerability is also tracked by ENISA as EUVD-2017-11528 in the EU Vulnerability Database. Last updated in EUVD on September 17, 2024.
View on the EU Vulnerability DatabaseAffected products
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
- juniper / junos
and 87 more…
Certified products that may be affected
1 FIPS 140 or Common Criteria certified product, from automated matching by sec-certs.org.
- Juniper Networks SRX345/SRX345-DUAL-AC with Junos 15.1X49-D110 - Juniper Networks, Inc. - FIPS 140 3247 - historical
References
- http://www.securityfocus.com/bid/99567(Third Party Advisory, VDB Entry)
- http://www.securitytracker.com/id/1038903(Third Party Advisory, VDB Entry)
- https://kb.juniper.net/JSA10793(Vendor Advisory)
Last updated September 17, 2026 · Source: NVD, CISA KEV, FIRST.org EPSS
Query CVEs from your AI assistant
The CVE/NVD Explorer brain answers CVE questions directly inside Claude, ChatGPT, or any MCP assistant — always up to date, no setup. Add it once and stop pasting advisories into chat.
Add the CVE brain