kbrain

CVE-2013-5022

HIGH · CVSS 10.0EPSS 2.6%EU EUVD

Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.

Key facts

CVSS score
10.0 (v2.0)
Severity
HIGH
CVSS vector
AV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness (CWE)
CWE-22
EPSS score
2.6% (85th percentile)
In CISA KEV
No
In EU EUVD
Yes (EUVD-2013-4864)
Published
August 6, 2013
NVD last modified
June 16, 2026
Status
Modified

EU Vulnerability Database (EUVD)

This vulnerability is also tracked by ENISA as EUVD-2013-4864 in the EU Vulnerability Database. Last updated in EUVD on August 6, 2024.

View on the EU Vulnerability Database

Affected products

  • ni / labview
  • ni / labwindows
  • ni / measurementstudio
  • ni / teststand

References

Last updated September 17, 2026 · Source: NVD, CISA KEV, FIRST.org EPSS

Query CVEs from your AI assistant

The CVE/NVD Explorer brain answers CVE questions directly inside Claude, ChatGPT, or any MCP assistant — always up to date, no setup. Add it once and stop pasting advisories into chat.

Add the CVE brain